
ASC
hCG One Step Pregnancy Test Strip - EXPIRY: AUG 2025
hCG 25mIU/ml
as low as $0.26 each
Case of 100
Discounted Pricing (Buy More & Save More)
hCG One Step Pregnancy Test Strip – Case of 100 – ASC
The hCG One Step Pregnancy Test Strip offers a straightforward, trustworthy, and cost-effective way to detect pregnancy early, all from the comfort of home. Utilizing advanced pregnancy test technology, this strip delivers rapid and precise results by identifying the pregnancy hormone, hCG (human chorionic gonadotropin), in urine. With its high sensitivity, it can detect even minimal hCG levels, allowing you to confirm a pregnancy as soon as the first day of a missed period. The user-friendly design lets you simply dip the test strip into a urine sample, and results are available within minutes.
Features & Benefits:
- High Sensitivity and Accuracy
- Dual Detection & Rapid Results
- Essential for Overdose Prevention
- Portable and Compact
- Easy to use & One-Step
- Built-In Control Line
- Cost-Effective & Versatile Applications
- Over 99% Accurate
- Prevents Severe Health Complications
- FREE LAB SET UP to confirm positive.
- 24 Month Shelf Life from Date of manufacture
- FDA 510(k) and CLIA Waived
- FREE SHIPPING on 100 Test Strips and more
- Buy More & Save More Pricing Structure
- Buy Drug Test Strips in Bulk – Call Cody at 318.798.3306
List of hCG Test Strip & Cut-off levels
hCG Test Strips | Urine Cutoff Levels | Detection Time |
hCG (human Chorionic Gonadtropin) | 25mIU/ml | - |
These estimates serve as guidelines, yet the actual duration can vary widely based on factors such as the individual’s duration of drug use, dosage, and metabolism.
All our drug test kits follow the SAMHSA Cutoff Levels.
These estimates serve as guidelines, yet the actual duration can vary widely based on factors such as the individual’s duration of drug use, dosage, and metabolism.
These are screening devices only and although very accurate if you get a positive we recommend a certified lab for LC-MS/MS Confirmation. For more information dial 1-866-526-2873, or email sales@americanscreeningcorp.com
Why Choose American Screening Corp
American Screening Corp is one of the leading manufacturer and distributor of Urine Test Strips in USA. We offers wide range of test strips ranging from 1 panel to 10 panel drug test dip cards, some of our popular multi panel test strips are 1 Panel, 5 Panel & 10 Panel.
Superior Quality: Our drug test strips are high quality made with medical grade plastic.
Easy to Use: All our drug test strips are easy to use, instant and results in minutes.
Compliance with Standards: All our drug screening strips are compliance with standards.
Excellent Customer Service: Our support and customer service team will go beyond your expectations to help you choose the right urine test strips.
Guaranteed Lowest Pricing: We offer lowest possible price in the market with quantity discounts when you buy more.
FAQ – hCG One Step Pregnancy Test Strip
1. What is hCG?
hCG (Human Chorionic Gonadotropin) is a hormone naturally produced during pregnancy. It is commonly detected in pregnancy tests. However, in a medical or drug-related context, hCG is sometimes used as a performance-enhancing drug or for other therapeutic purposes.
2. What is the cut-off level?
The cut-off level for hCG is 25mIU/ml. This means the test will detect hCG at or above this concentration in the urine sample.
3. How does the test work?
- Dissolve a small sample of the substance in water.
- Dip the strip in the solution for about 15 seconds.
- Lay the strip on a flat surface and wait 2-5 minutes for results.
4. What is the shelf-life?
Shelf-life of the all drug test dip cards is 24 months from the date of manufacture.
5. How long does it take to get results?
Results are available within 5 minutes after dipping the card in the urine sample for 15 seconds.
6. How do I interpret the results?
Two lines (Control and Test lines): Negative result (no hCGdetected).
One line (Control line only): Positive result (hCG detected).
No lines or only a Test line: Invalid result (repeat the test with a new strip).
How it Works
Our 12 panel drug test cups are easy to use and the following step-by-step procedure helps you test in 3 easy steps.
1
Collect Specimen
Collect at least 30 mL of urine to activate the test, return to cup to collector for analysis.

2
Recap & Wait
Recap the cup and place the test on a flat surface, observing the temperature strip attached on the cup.

3
Read Results
Results should appear in 5 minutes or less. DO NOT read result after 10 minutes.

How to read 12 panel drug test cup

POSITIVE
When only one colored band appears in the control region (C). No apparent colored band appears in the test region (T).

NEGATIVE
When two colored bands appear on the membrane and one band appears in the control region (C) and another band appears in the test region (T).
Certain lines may appear lighter or thinner than other lines.
Each line is to be considered a clear reading whether it be faint, light or dark.

INVALID
An invalid result is when a control band completely fails to appear.
Drug
- Alcohol
- Amphetamine
- Amphetamine
- Barbiturates
- Benzodiazepines
- Buprenorphine
- Cannabinoids
- Cocaine
- Cocaine
- Cotinine
- Ecstasy
- Ethylglucuronide
- Fentanyl
- Ketamine
- Kratom
- Lysergic Acid Diethylamide
- Methadone
- Methadone (EDDP)
- Methamphetamine
- Methamphetamine
- Methaqualone
- Methylphenidate
- Opiates
- Opiates (Morphine)
- Oxycodone
- Phencyclidine
- Propoxyphene
- Synthetic Cannabinoids
- Tramadol
- Tricyclic Antidepressants
Abbreviation
- ALC or ALCO
- AMP
- AMP300
- BAR
- BZO
- BUP
- THC
- COC
- COC150
- COT
- MDMA
- ETG
- FEN or FENT
- KET
- KRA
- LSD
- MTD
- EDDP
- MAMP or MET
- MAMP500 or MET500
- MQL
- MTHP
- OPI or OPl2000
- MOR or OPl300
- OXY
- PCP
- PPX
- K2
- TRA or TRAM
- TCA
Urine Cutoff· Level
- 20 mg/dl
- 1,000 ng/mL
- 300 ng/ml
- 300 ng/ml
- 300 ng/ml
- 10 ng/ml
- 50 ng/ml
- 300 ng/ml
- 150 ng/ml
- 200 ng/ml
- 500 ng/ml
- 500 ng/ml
- 10 ng/ml
- 1000 ng/ml
- 250 ng/ml
- 10 ng/ml
- 300 ng/ml
- 300 ng/ml
- 1,000 ng/mL
- 500 ng/ml
- 300 ng/ml
- 300 ng/ml
- 2,000 ng/mL
- 300 ng/ml
- 100 ng/ml
- 25 ng/ml
- 300 ng/ml
- 50 ng/ml
- 300 ng/ml
- 1,000 ng/mL
Saliva Cutoff· Level
- >0.02%B.A .C.
- 50 ng/ml
- 50 ng/ml
- 50 ng/ml
- 10 ng/ml
- 12 ng/ml
- 20 ng/ml
- 35 ng/ml
- 50 ng/ml
- 40 ng/ml
- 50 ng/ml
- 10 ng/ml
Approximate Detection Time in Urine
- Up to 24 Hours
- 2-4 Days
- 2-4 Days
- 4-7 Days
- 3-7 Days
- 1-4 Days
- 15-30 Days
- 2-4 Days
- 2-4 Days
- 2-3 Days
- 1-3 Days
- Up to 80 Hours
- 3-4 Days
- 7-14 Days
- 1-3 Days
- 2-5 Days
- 3-5 Days
- 3-5 Days
- 3-5 Days
- 3-5 Days
- Up to 6 Days
- 1-2 Days
- 2-4 Days
- 2-4 Days
- 2-4 Days
- 7-14 Days
- 1-2 Days
- Up to 3 Days
- 1-7 Days
- 7-10 Days
Approximate Detection Time in Saliva
- Up to 24 Hours
- 1-3 Days
- 1-3 Days
- 1-16 Hours
- 4-8 Hours
- 48-72 Hours
- 6-12 Hours
- 1-3 Days
- 1-3 Days
- 24-48 Hours
- 24-48 Hours
- Up to 80 Hours
- 24-48 Hours
- 24-48 Hours
- –
- 12-24 Hours
- 12-24 Hours
- 48-72 Hours
- 1-3 Days
- 1-3 Days
- 48-72 Hours
- 24-48 Hours
- 1-3 Days
- 1-3 Days
- 1-3 Days
- 1-3 Days
- 48-72 Hours
- 1-2 Days
- 48-72 Hours
Weight | 0.001 lbs |
---|---|
Dimensions | 9 × 7 × 4 in |
Adulterants |
No |
Drugs Tested For | hCG |
Number of Drugs Tested | 1 |